Brand Name : LABNOVATION

Model Number : LX-401701

Certification : ISO13485, ISO9001, CE

Place of Origin : China

MOQ : 10000/Pieces

Price : US $0.7-1/Piece

Payment Terms : D/A, D/P, T/T

Supply Ability : 500000/Day

Delivery Time : 5-7 work day

Packaging Details : Carton

Specimen : Serum, Plasma, Whole Blood

Storage : 2℃-30℃

Group : Universal

Test Speed : Within 15 minutes

Accuracy : >95.00%

Contact Now

Rapid Antibody Rapid Test Kit SARS-CoV-2 Neutralizing Antibody Rapid test Kit High Quality Test Kit


Intended Use
The SARS-COV-2 Neutralizing Antibody Rapid Test Kit is a lateral flow immunoassay intended for the semi-quantitative determination of neutralizing antibodies (NAbs) to SARS-COV-2 that block the interaction between the receptor binding domain (RBD) of the viral spike glycoprotein with the ACE2 cell surface receptor in human serum, plasma (EDTA and sodium citrate), whole blood specimens.The test is intended use as an aid in identifying individuals with an adaptive immune response to SARS-COV-2, indicating recent or prior infection or assisting in evaluating the effectiveness of the vaccine clinical trials and mass vaccination.

Specifications

Test Item Neutralizing Antibody Test Kit
Number LX-401701
Specimen Type Whole blood, Serum, Plasma
Sample Volume Whole blood 20µL, Serum/Plasma 10µL
Package 20 Test/Box
Specificity 98.00%
Sensitivity 97.67%
nspection Method Immunochromatography
Shelf Life 18 Months
Type IVD Antibody Rapid Test

CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis
Main Components

  • 20 Test cassettes
  • 20 Disposable pipettes
  • 20 Sterile Safety Lancets
  • 1 Sample Buffer
  • 1 Colorimetric chart
  • 1 Instruction for use

Product Feature

  • Blood testing, Fingerstick whole blood is workable.
  • Easy to operate, no additional material required to run the assay
  • Little Specimen is enough ​
  • High Accurracy, Specificity and Sensitivity

CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis
Advantage

  • Accurate: the product has a high accurate serology test for Neutralizing Antibodies detection

  • Easy to administer and read results: no need for instrument or other equipment during the test

  • Fast detection: the result appears in 10 minutes, can be used for testing on a massive scale.

  • No specific storage requirement: room temperature (2-30ºC)

Use Step

  • Place the lanceton the test site.
  • Push down the lancet.
  • Collect the bloodby transfer pipette.

CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis

  • Add one drop of blood into the sample well.
  • Add 1-2 drops (30-60µL) of sample buffer into the sample well innediately.
  • Wait 15 minutes then read the result.

CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis

Interpretation of results

  • POSITIVE: The T line and C line are both displayed within the reaction window, indicates the neutralizing antibodies to SARS-COV-2 are detected. The result is positive.
  • NEGATIVE:The C line is displayed within the reaction window only, indicates absence of neutralizing antibody to SARS-COV-2.The result is negative..
  • INVALID:1. If the control (C) line is not displayed in 15 min, regardless of whether T line is present, the test result is invalid. It is recommended that the specimen should be re-tested.
    The test result is invalid after 20 min.

CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis

Applicaton

  • Evaluation of Vaccination
  • Diagnosis of Infection
  • Assessment of Convalescent Plasama Therapy
  • Epidemiology Research

Storage and Expiry

The kit should be sealed and stored at 2-30°C, protected from light, heat, and stored in a dry place. The validity period is tentatively set at 24 months and cannot be stored in freezing. Some protective measures should be taken in hot summer and cold winter to avoid high temperature or freeze-thaw. Do not open the inner packaging until ready, it must be used in one hour if opened
FAQ

  • MOQ:

We have the MOQ limit,which is 10000 pieces.

  • Delivery date:

After order confirmed,we will arrange your order immediately,and offer you an
estimated delivery date.

  • Payment Method:

Business to business account.

  • Shipment:

We choose Air cargo or Ocean cargo.

  • Trade Company or Manufacturer:

Manufacturer


Product Tags:

CE Neutralization Antibody Detection Kit

      

NAbs Neutralization Antibody Detection Kit

      

SARS CoV 2 neutralizing antibody kit

      
 CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis Manufactures

CE SARS CoV 2 Neutralization Antibody Detection Kit For Infection Diagnosis Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)